Description
Model | KLD-RD3.5kW-1-L |
---|---|
Power | 3.5kVA / 3.5kW |
Number of units in parallel | Not supported |
Operating temperature | – 10 °C ~50 °C |
Storage temperature | – 15 °C ~50 °C |
Humidity | 5% to 95% relative humidity (non-condensing) |
Communication method | RS232+RS485 |
Lithium battery activation | Supported |
Lithium battery communication | Supported |
Input | |
Rated voltage | 230VAC |
Voltage range | 170 – 280VAC ; 90 – 280VAC |
Frequency | 50/60Hz (auto-sensing) |
PV charging method | MPPT |
Maximum PV input power | 4000W |
Maximum PV open circuit voltage | 500VDC |
MPPT voltage range | 60VDC~500VDC |
Number of MPPTs/maximum input current | 1/15A |
Output | |
Rated voltage | 220/230VAC ± 5% |
Instantaneous power | 7000VA |
Frequency | 50/60Hz |
Output waveform | Pure sine wave |
Conversion time | 10ms (computer); 20ms (household appliances) |
Peak efficiency (photovoltaic/battery inverter) | 96%/93% |
Overload protection | 5s≥150% load; 10s≥110%~150% load |
Peak factor | 3:01 |
Power factor | 0.6~1 (capacitive or inductive) |
Battery & Charging | |
Battery voltage | 24VDC |
Float charge voltage | 27VDC |
Overcharge protection | 33VDC |
Charging method | CC/CV |
Maximum PV charging current | 100A |
Maximum utility charging current | 80A |
Maximum charging current | 100A |
Degree of protection | IP20 |
Model | KLD-RD5kW-1-H | KLD-RD6kW-1-H |
---|---|---|
Number of phases | Single-phase input/output | |
Output power | 5.5kVA/5.5kW | 6.2kVA/6.2kW |
Number of units in parallel | 12 units | |
Humidity | -10°C~50°C | |
Operating temperature | -15°C~50°C | |
Communication method | 5% to 95% relative humidity (non-condensing) | |
Lithium communication | Supported | |
Off-grid mode | ||
Utility input | ||
AC start-up voltage/auto-restart voltage | 100VAC/90VAC | |
Acceptable input voltage range | 170-280VAC or 90-280VAC | |
Maximum utility input current | 40A | |
PV input (DC) | ||
Maximum DC voltage | 500VDC | |
Maximum power | 5500VA/5500W | 6200VA/6200W |
MPPT voltage range | 120VDC~450VDC | 60VDC~500VDC |
Number of MPPTs/maximum input current | 1/18A | 1/27A |
Battery mode output (AC) | ||
Rated output voltage | 220/230/240VAC | |
Output waveform | Pure sine wave | |
Efficiency (DC to AC) | 94% | |
Hybrid mode | ||
PV input (DC) | ||
Rated DC voltage/maximum DC voltage | 360VDC/500VDC | |
Start-up voltage/initial feed-in voltage | 150VDC/120VDC | |
Maximum power | 5500VA/5500W | 6200VA/6200W |
MPPT voltage range | 120VDC~450VDC | 60VDC~500VDC |
Number of MPPTs/maximum input current | 1/18A | 1/27A |
Utility output (AC) | ||
Rated output voltage | 220/230/240VAC | |
Output voltage range | 170-280VAC or 90-280VAC | |
Rated output current | 22A | 22A |
Utility input | ||
AC start-up voltage/auto-restart voltage | 100VAC/90VAC | |
Acceptable input voltage range | 170-280VAC or 90-280VAC | |
Maximum utility input current | 40A | |
Battery mode output (AC) | ||
Rated output voltage | 220/230/240VAC | |
Efficiency (DC to AC) | 94% | |
Battery & Charging | ||
Rated DC voltage | 48VDC | 48VDC |
Maximum solar charging current | 100A | 120A |
Maximum utility charging current | 60A | 80A |
Maximum charging current | 100A | 120A |
Degree of protection | IP20 |